Přehled o publikaci
2024
Development of a supramolecular solvent–based extraction method for application to quantitative analyses of a wide range of organic contaminants in indoor dust
MARCINEKOVÁ, Paula; Lisa Emily MELYMUK; Pernilla BOHLIN-NIZZETTO; Erika MARTINELLI; Simona Rozárka JÍLKOVÁ et al.Základní údaje
Originální název
Development of a supramolecular solvent–based extraction method for application to quantitative analyses of a wide range of organic contaminants in indoor dust
Autoři
MARCINEKOVÁ, Paula; Lisa Emily MELYMUK; Pernilla BOHLIN-NIZZETTO; Erika MARTINELLI; Simona Rozárka JÍLKOVÁ; Jakub MARTINÍK; Petr ŠENK; Petr KUKUČKA; Ondřej AUDY; Jiří KOHOUTEK; Mebrat GHEBREMESKEL; Alexander HÅLAND; Anders RØSRUD BORGEN; Heidi EIKENES; Linda HANSSEN; Mikael HARJU; Zofia CEBULA a Pawel ROSTKOWSKI
Vydání
Analytical and Bioanalytical Chemistry, Springer Heidelberg, 2024, 1618-2642
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14310/24:00136517
Organizace
Přírodovědecká fakulta – Masarykova univerzita – Repozitář
UT WoS
EID Scopus
Klíčová slova anglicky
SUPRAS; Indoor environments; Plastic additives; Pesticides; PFAS
Návaznosti
GA22-32743S, projekt VaV. 857560, interní kód Repo. RECETOX RI II, velká výzkumná infrastruktura.
Změněno: 28. 5. 2025 00:50, RNDr. Daniel Jakubík
Anotace
V originále
This study investigates the efficacy of supramolecular solvent (SUPRAS) in extracting a diverse spectrum of organic contaminants from indoor dust. Initially, seven distinct SUPRAS were assessed across nine categories of contaminants to identify the most effective one. A SUPRAS comprising Milli-Q water, tetrahydrofuran, and hexanol in a 70:20:10 ratio, respectively, demonstrated the best extraction performance and was employed for testing a wider array of organic contaminants. Furthermore, we applied the selected SUPRAS for the extraction of organic compounds from the NIST Standard Reference Material (SRM) 2585. In parallel, we performed the extraction of NIST SRM 2585 with conventional extraction methods using hexane:acetone (1:1) for non-polar contaminants and methanol (100%) extraction for polar contaminants. Analysis from two independent laboratories (in Norway and the Czech Republic) demonstrated the viability of SUPRAS for the simultaneous extraction of twelve groups of organic contaminants with a broad range of physico-chemical properties including plastic additives, pesticides, and combustion by-products. However, caution is advised when employing SUPRAS for highly polar contaminants like current-use pesticides or volatile substances like naphthalene.