Přehled o publikaci
2018
A Neutron Spectrometer for Experiments with Radioactive Beams on the ACCULINNA-2 Fragment Separator
BEZBAKH, A. A.; S. G. BELOGUROV; R. WOLSKI; E. M. GAZEEVA; M. S. GOLOVKOV et. al.Basic information
Original name
A Neutron Spectrometer for Experiments with Radioactive Beams on the ACCULINNA-2 Fragment Separator
Authors
BEZBAKH, A. A. (643 Russian Federation); S. G. BELOGUROV (643 Russian Federation); R. WOLSKI (616 Poland); E. M. GAZEEVA (643 Russian Federation); M. S. GOLOVKOV (643 Russian Federation); A. V. GORSHKOV (643 Russian Federation); G. KAMINSKI (616 Poland); M. Yu. KOZLOV (643 Russian Federation); S. A. KRUPKO (643 Russian Federation); Ivan MUZALEVSKII (643 Russian Federation, belonging to the institution); E. Yu. NIKOLSKII (643 Russian Federation); E. V. OVCHARENKO (643 Russian Federation); R. S. SLEPNEV (643 Russian Federation); G. M. TER-AKOPIAN (643 Russian Federation); A. S. FOMICHEV (643 Russian Federation); Vratislav CHUDOBA (203 Czech Republic, guarantor, belonging to the institution); P. G. SHAROV (643 Russian Federation) and V. N. SCHETININ (643 Russian Federation)
Edition
Instruments and Experimental Techniques, 2018, 0020-4412
Other information
Language
English
Type of outcome
Article in a journal
Field of Study
21100 2.11 Other engineering and technologies
Country of publisher
United States of America
Confidentiality degree
is not subject to a state or trade secret
References:
RIV identification code
RIV/47813059:19240/18:A0000361
Organization
Filozoficko-přírodovědecká fakulta – Slezská univerzita v Opavě – Repository
UT WoS
000445896400001
EID Scopus
2-s2.0-85053911519
Keywords in English
neutron spectrometer; stilbene crystals; ACCULINNA-2; instrumentation engineering
Tags
Tags
International impact, Reviewed
Changed: 5/4/2019 13:19, Jan Hladík
Abstract
V originále
A neutron spectrometer based on stilbene crystals has been developed by the Flerov Laboratory of Nuclear Reactions at the Joint Institute for Nuclear Research (Dubna, Russia). The timing resolution is determined as a function of the signal amplitude (sigma T = 0.18 ns at an amplitude of 1 MeV in the electron equivalent). The measured energy resolution of the detecting modules for gamma rays is sigma E/E = 4.5% at E = 1 MeV. The quality of the n-gamma discrimination is investigated. It is shown that reliable discrimination is possible, beginning with a deposited energy of 100 keV in the electron equivalent, which corresponds to the kinetic energy of recoil protons of ~ 700 keV. The neutron spectrometer helps to significantly expand the experimental capabilities and to carry out correlation experiments with radioactive beams on the ACCULINNA-2 fragment separator at a new level of quality.