Respiratory arrhythmia as an encouragement of inappropriate ICD therapy

česky | in English

Přihlášení

eduID.cz
 
KORPAS, David, Jana HALUZÍKOVÁ, Marek PENHAKER a Martin AUGUSTYNEK. Respiratory arrhythmia as an encouragement of inappropriate ICD therapy. Lékař a technika - Clinician and Technology, Czech Society for Biomedical Engineering and Medical Informatics and the Faculty of Biomedical Engineering, Czech Technical University, 2016, roč. 46, č. 3, s. 69-73. ISSN 0301-5491.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Respiratory arrhythmia as an encouragement of inappropriate ICD therapy
Název česky Respirační arytmie jako příčina nevhodné terapie ICD
Autoři KORPAS, David (203 Česká republika, garant, domácí), Jana HALUZÍKOVÁ (203 Česká republika, domácí), Marek PENHAKER (203 Česká republika) a Martin AUGUSTYNEK (203 Česká republika).
Vydání Lékař a technika - Clinician and Technology, Czech Society for Biomedical Engineering and Medical Informatics and the Faculty of Biomedical Engineering, Czech Technical University, 2016, 0301-5491.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor Cardiac and Cardiovascular systems
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW URL
Kód RIV RIV/47813059:19510/16:A0000092
Organizace Fakulta veřejných politik v Opavě - Slezská univerzita v Opavě
Klíčová slova anglicky implantable cardioverter-defibrillator; respiration; inappropriate shock
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Petra Skoumalová, učo 1141. Změněno: 17. 4. 2019 10:16.
Anotace
Implantable cardioverter-defibrillators (ICDs) are active cardiac implants for immediate treatment of ventricular arrhythmias. They provide life-saving therapy, but may also deliver inappropriate therapy. These two cases demonstrate a possibility of ICD therapy detection or induction encouraged by physiological patient breathing. The cases of 64-year-old and 30-year-old women patients are reported. The first one has received some therapy, the second one has not. The devices records did not show any abnormalities in trends or electrical parameters. As a solution, the detection parameters of the devices were optimized, with reference to individual physiologically reachable heart rates of the patients.