SALAČ, Petr a Václav DVOŘÁK. Shape optimization of the current body located in the cooling canal. Online. In Venkov G., Pasheva V. AIP Conf. Proc. 1631. AIP Conf. Proc. 1631. Melvill, NY, USA: American Institute of Physics Inc., 2014, s. 104-110. ISBN 978-0-7354-1270-5. Dostupné z: https://dx.doi.org/10.1063/1.4902465.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Shape optimization of the current body located in the cooling canal
Autoři SALAČ, Petr (203 Česká republika, garant, domácí) a Václav DVOŘÁK (203 Česká republika).
Vydání AIP Conf. Proc. 1631. Melvill, NY, USA, AIP Conf. Proc. 1631, od s. 104-110, 7 s. 2014.
Nakladatel American Institute of Physics Inc.
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 20000 2. Engineering and Technology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání elektronická verze "online"
WWW URL
Kód RIV RIV/46747885:24510/14:#0001205
Organizace Fakulta přírodovědně-humanitní a pedagogická – Technická univerzita v Liberci – Repozitář
ISBN 978-0-7354-1270-5
ISSN 0094-243X
Doi http://dx.doi.org/10.1063/1.4902465
UT WoS 000346058100016
Klíčová slova anglicky Shape optimization; conduction of heat in stationary flow; incompressible potential flow
Příznaky Mezinárodní význam, Recenzováno
Návaznosti TA03010852, projekt VaV.
Změnil Změnil: Petr Salac, učo 498. Změněno: 3. 4. 2015 11:30.
Anotace
Shape optimization of the current body located in the cooling canalThe contribution is the second step of the optimization process introduced on AMEE’13 where the position of cooling canal was searched. In this paper the outward shape of the regulation current body located in the axis of the system is optimized to obtain required temperature on the outward surface of the tube. The algorithm was designed and debugged for simplified model, in which the plunger is replaced by the tube, which is surrounded by thermal source representing cooled glass moulded piece from outward, and the cooling water of temperature 15oC on input flowing through. The state problem is formulated as a stationary heat conduction process. The cost functional is taken as the second power of L2 distance of temperature from the given constant value on the outward boundary of the tube. The results of the numerical optimization to three required target temperatures 700, 750 and 800oC of the outward tube surface together with the distribution of temperatures on the interface between the tube and the heat source before and after the optimization process are presented