J
2013
Optimal design of the cooling plunger cavity
SALAČ, Petr
Basic information
Original name
Optimal design of the cooling plunger cavity
Authors
SALAČ, Petr (203 Czech Republic, guarantor, belonging to the institution)
Edition
Applications of Mathematics, 2013, 0862-7940
Other information
Type of outcome
Article in a journal
Field of Study
General mathematics
Country of publisher
Czech Republic
Confidentiality degree
is not subject to a state or trade secret
RIV identification code
RIV/46747885:24510/13:#0000997
Organization
Faculty of Science, Humanities and Education – Technical University of Liberec – Repository
Keywords in English
energy transfer
Links
MSM4674788501, plan (intention).
V originále
An axisymmetric system of mould, glass piece, plunger and plunger cavity is considered. The state problem is given as a stationary head conduction process. The system has given heat source representing glass piece and is cooled by flowing water inside the plunger cavity and outside by environment of the mould. The design variable is taken to be the shape of inner surface of the plunger cavity. The cost functional is the second power of the norm in the weighted space $ L^2_r $ of difference of trace of temperature from given constant, which is evaluated on the outward boundary of the plunger. Existence and uniqueness of the state problem solution and existence of a solution of the optimization problem are proved.
Displayed: 4/7/2025 07:37