J 2013

Optimal design of the cooling plunger cavity

SALAČ, Petr

Basic information

Original name

Optimal design of the cooling plunger cavity

Authors

SALAČ, Petr (203 Czech Republic, guarantor, belonging to the institution)

Edition

Applications of Mathematics, 2013, 0862-7940

Other information

Language

English

Type of outcome

Article in a journal

Field of Study

General mathematics

Country of publisher

Czech Republic

Confidentiality degree

is not subject to a state or trade secret

References:

RIV identification code

RIV/46747885:24510/13:#0000997

Organization

Faculty of Science, Humanities and Education – Technical University of Liberec – Repository

Keywords in English

energy transfer

Links

MSM4674788501, plan (intention).
Changed: 10/3/2015 13:50, RNDr. Daniel Jakubík

Abstract

V originále

An axisymmetric system of mould, glass piece, plunger and plunger cavity is considered. The state problem is given as a stationary head conduction process. The system has given heat source representing glass piece and is cooled by flowing water inside the plunger cavity and outside by environment of the mould. The design variable is taken to be the shape of inner surface of the plunger cavity. The cost functional is the second power of the norm in the weighted space $ L^2_r $ of difference of trace of temperature from given constant, which is evaluated on the outward boundary of the plunger. Existence and uniqueness of the state problem solution and existence of a solution of the optimization problem are proved.