Přehled o publikaci
2014
Digitalized two parametric system for gamma/neutron spectrometry
VEŠKRNA, Martin; Zdeněk MATĚJ; Filip MRAVEC; Václav PŘENOSIL; František CVACHOVEC et al.Basic information
Original name
Digitalized two parametric system for gamma/neutron spectrometry
Name in Czech
Digitalizovaný dvouparametrický systém pro gamma/neutron spektrometrii
Authors
VEŠKRNA, Martin; Zdeněk MATĚJ; Filip MRAVEC; Václav PŘENOSIL; František CVACHOVEC and Michal KOŠŤÁL
Edition
Knoxville, USA, 18th Topical Meeting of the Radiation Protection and Shielding Division (RPSD 2014), p. 1-4, 4 pp. 2014
Publisher
American Nuclear Society
Other information
Language
English
Type of outcome
Proceedings paper
Field of Study
Computer hardware and software
Country of publisher
United States of America
Confidentiality degree
is not subject to a state or trade secret
Publication form
electronic version available online
Marked to be transferred to RIV
Yes
RIV identification code
RIV/00216224:14330/14:00073299
Organization
Fakulta informatiky – Repository – Repository
ISBN
978-0-89448-714-9
Keywords (in Czech)
gama/neutronová spektrometrie, diskriminace; PSD; spektrometrie; dvouparametrický spektrometr; neutronová spektrometrie
Keywords in English
gamma/neutron spectrometry; discrimination; spectrometry; PSD; two-parameter spectrometer; neutron spectrometry
Links
TA01011383, research and development project.
Changed: 1/9/2020 22:56, RNDr. Daniel Jakubík
In the original language
Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included.
In Czech
Článek popisuje spektrometr pro měření ve směsných polích gama/neutrony. Analogový signál z detektoru je vzorkován AD převodníky pracujícími na frekvenci 1 GHz. Předzpracování signálu probíhá v FPGA a tím je zajištěna vysoká propustnost systému bez mrtvé doby. Spektrometr byl testován v Centru výzkumu Řež na reaktoru LR-0.